Symmons TA-25B-RP Installation Guide

Browse online or download Installation Guide for Sanitary ware Symmons TA-25B-RP. Symmons TA-25B-RP Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Single Handle Pressure-Balancing Mixing Valve for Shower or Tub/Shower Application
INSTALLATION, OPERATION & SERVICE INSTRUCTIONS
Symmons valves and shower heads comply to all known standards, codes and
specifications: CSA B-125, ANSI A112.18.1M, ASSE 1016, EPA ‘92 etc.
Symmons shower heads are equipped with a 2.5 GPM (9.5 L/min) water and energy
saving flow restrictor..
IMPORTANT: After completion of installation step 4, follow these instructions to set the
Temptrol Limit Stop Screw. This valve is equipped with a limit stop screw to be used to
limit valve handle from being turned to excessively hot water discharge temperatures.
To adjust, remove dome cover, open valve to maximum desired temperature and turn
in limit stop screw until it seats.
WARNING: FAILURE TO AdjUST ThE LIMIT STOP SCREW PROPERLy MAy RESULT
IN SERIOUS SCALdING.
WARNING: ThIS ShOWER SySTEM MAy NOT PROTECT ThE USER FROM SCALdING
WhEN ThERE IS A FAILURE OF OThER TEMPERATURE CONTROLLING dEVICES
ELSEWhERE IN ThE PLUMbING SySTEM.
For ADA compliance (Americans with Disabilities Act) consult ADAAG or your state
regulations for proper product choice and mounting locations.
PLEASE REAd ALL INSTRUCTIONS CAREFULLy bEFORE STARTING
INSTALLATION. SAVE ThIS MANUAL FOR FUTURE REFERENCE.
LIFETIME LIMITEd WARRANTy
Symmons warrants to the original consumer purchaser that any TEMPTROL® series* or SYMMETRIX®
product will be free of defects in material and workmanship during normal domestic use for the life of
your home. All other products and purchasers including industrial, commercial or business use are
warranted for a period of 5 years from the date of purchase. At our option, we will either have you send
the defective part or product prepaid to us for inspection, or we may elect to send you the replacement
part or product without investigation. A replacement for any defective part will be supplied FREE OF
CHARGE for installation by the purchaser. Defect or damage caused by the use of replacement parts
other than Symmons Genuine Replacement Parts will void this warranty. This warranty excludes product
damage due to installation error, product abuse, or product misuse whether performed by a contractor,
service company or yourself.Symmons further warrants that any TEMPTROL or SYMMETRIX product will
be leak free and drip free during normal domestic use for the life of your home. If the product should
develop a leak or drip, Symmons will provide FREE OF CHARGE the parts necessary to return it to good
working condition.Proof of purchase (original sales receipt) and a copy of the warranty registration card
from the original consumer purchaser must accompany all warranty claims. This warranty is applicable
only to Symmons TEMPTROL or SYMMETRIX products purchased after July 1, 1998 and shall be effective
from the date of purchase as shown on the purchaser’s receipt.Damage to the chrome and/or other
decorative finishes on Symmons products may be a result of improper handling or abusive treatment.
Finishes should only be cleaned with a soft, damp cloth or sponge. Use of polish, abrasive cleaners,
solvents, or acid cleaners will damage the finish and void this warranty.There are no other express
warranties on this product and ALL WARRANTIES OF MERCHANTABILITY AND OTHER IMPLIED
WARRANTIES ARE LIMITED IN ACCORDANCE WITH APPLICABLE LAW. SYMMONS INDUSTRIES, INC.,
EXPRESSLY DISCLAIMS CONTINGENT LIABILITY AND CONSEQUENTIAL DAMAGE OF EVERY KIND. Since
some states do not allow limitations on how long an implied warranty lasts or an
exclusion or limitation
of incidental or consequential damages the above limitation or exclusion may not be applicable. This
warranty gives specific legal rights. Other rights may vary from state to state.To obtain warranty service,
write to Symmons Industries, Inc., 31 Brooks Drive, Braintree, MA 02184-3804 or call our Customer
Service Department at 1-800-SYMMONS. If writing to us, please include proof of purchase, the model
number of the product with a brief description of the problem, your name, address and phone number.
*Temptrol series includes Allura®, Olde Braintree Brass®, Temptrol, Temptrol Deluxe and Temptrol II
shower and tub/shower systems.
Temptrol®
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Temptrol®

Single Handle Pressure-Balancing Mixing Valve for Shower or Tub/Shower ApplicationINSTALLATION, OPERATION & SERVICE INSTRUCTIONSSymmons valves and

Page 2 - FIGURE 2A

INSTALACIÓN ENCONTRADA (ESPALDA CON ESPALDA)Para simplificar la instalación de la tubería en las instalaciones espalda con espalda, utilice una válvula

Page 3 - FIBERGLASS WALL INSTALLATION

PIEZAS INDIVIDUALES PIEZAS INDIVIDUALESPIEZAS COMPUESTASPIEZAS COMPUESTAS y/o del volumenT-32 Tornillo de la palanca con arandela de seguridadT-33

Page 4 - THICKNESS

CUADRO DE SOLUCIÓN DE PROBLEMASMANTENIMIENTO1. Cierre el abasto de agua a la válvula.2. Saque el botón taponador de la palanca y la palanca (véase l

Page 5 - COMPOSITE PARTS

INSTALLATION OF: SHOWER SYSTEMS AND TUB/SHOWER SYSTEMSTools required for installation of this product are: Phillips screw driver, tubing cutter, teflon

Page 6 - 3%2)%33%26)#%).3425#4)/.3

PAGE ONE. Reattach dome cover back onto packing nut.6. Mount gasket (T-27B) onto back of escutcheon with opening at bottom as shown in Figure 4. The

Page 7 - Temptrol

BACK TO BACK INSTALLATIONTo simplify piping on back to back installations use one stan-dard valve (hot on left, cold on right) and one with reverse co

Page 8 - FIGURA 2A

INDIVIDUAL PARTS INDIVIDUAL PARTSCOMPOSITE PARTSCOMPOSITE PARTSSC-15A Handle set screwT-1 Hot renewable seatT-2 Cold seat O-ringT-3 Cold renewable

Page 9 - A. B

TROUBLE SHOOTING CHART0ROBLEM #AUSE 3OLUTION&OLLOWSERVICEINSTRUCTIONS6ALVEWILLNOTPASSWATER (OTANDCOLDWATERNOTTURNEDON 4URNONBOT

Page 10 - DE LA PARED

Válvula mezcladora y reguladora de presión con palanca individual para aplicación en duchas o en sistemas de ducha y bañera.INSTRUCCIONES DE INSTALACI

Page 11 - PIEZAS COMPUESTAS

INSTALACIÓN DE: SISTEMAS DE DUCHA Y SISTEMAS DE BAÑERA/DUCHALas herramientas necesarias para la instalación de este producto son: Un destornillador e

Page 12 - ■ ZV-89S ■ 032108

EN LA NOTA “IMPORTANTE” QUE APARECE CON LETRAS EN NEGRITA, EN LA PRIMERA PÁGINA. Vuelva a colocar la cubierta sobre la tuerca del estopero.6. Monte e

Comments to this Manuals